Hytem offers a complete range of loads designed to meet dissipation needs in test environments, including water-cooled, oil-cooled, and air-cooled loads. Available for power levels up to 80 kW, they ensure reliable termination, low reflection (VSWR), and optimal thermal management for your RF transmission equipment.
Solutions suitable for high power up to 80 kW, meeting the demands of test benches and intensive RF systems.
Available in air, oil, or water-cooled versions for optimized thermal management according to the application.
Excellent impedance matching ensuring stable termination and limiting reflected waves.
Design engineered to guarantee continuous and safe operation, even under high load.
Ideal for testing transmitters, RF amplifiers, and industrial transmission systems.
Resistant materials ensure durability and consistent performance over time.
Formats suitable for fixed installations and professional measurement benches.
Water-cooled RF loads are essential devices for high-power transmission systems, enabling efficient dissipation of RF energy while minimizing ambient heat. Thanks to their compact design and ability to be installed in any position, they offer optimal flexibility for a variety of applications.
Our oil-cooled RF loads are designed to test and adjust high-power transmitters in non-radiating conditions. They offer virtually reflection-free termination, high accuracy, and safe heat dissipation thanks to a dielectric oil cooling system. Robust, reliable, and available in a wide range of power ratings, they can be adapted to your most demanding test environments.
For applications ranging from DC to 6 GHz, with a continuous power rating of 2 W.
It offers an impedance of 50 Ohms and a low SWR of 1.15:1.
For continuous power dissipation up to 15 W, covering a frequency range from DC to 3800 MHz.
It guarantees a stable impedance of 50 Ohms and a maximum SWR of 1.30:1.
Use this fixed RF load to efficiently handle signals up to 30 W continuously, in a wide frequency range from DC to 4000 MHz.
Equipped with a 7/16 male connector, integrate this fixed RF load into your system to dissipate up to 50 W continuously over a frequency range from DC to 3000 MHz.
Equipped with a male BNC connector, designed for applications up to 30 W continuous power over a frequency range from DC to 3000 MHz.
Equipped with a male BNC connector, designed for applications up to 30 W continuous power over a frequency range from DC to 3000 MHz.
Ensure reliable and stable dissipation with this compact RF load featuring an N-type male connector, designed to handle up to 2 W continuously over a frequency range from DC to 6000 MHz.
Equipped with a male C connector covering a band from DC to 3 GHz, with a continuous power rating of 2 W.
Designed for high-frequency applications, this RF load with SMA male connector covers a band from DC to 6 GHz and supports 2 W of continuous power.
Ultra-compact and precise, this RF N male connector is designed for low power applications up to 0.5 W continuous, with a bandwidth ranging from DC to 6000 MHz.
Male RF N connector allows continuous dissipation of 30 W over a wide frequency range from DC to 3000 MHz.
Covers a very wide frequency range from DC to 18 GHz.
Ultra-compact and designed for precision, this 50-ohm RF termination offers 2 W continuous power dissipation up to 6 GHz.
Compact and robust, this 50-ohm RF load supports up to 50 W continuously over an extended bandwidth of up to 4 GHz.
For applications ranging from DC to 6 GHz, with a continuous power rating of 2 W.
It offers an impedance of 50 Ohms and a low SWR of 1.15:1.
For continuous power dissipation up to 15 W, covering a frequency range from DC to 3800 MHz.
It guarantees a stable impedance of 50 Ohms and a maximum SWR of 1.30:1.
Use this fixed RF load to efficiently handle signals up to 30 W continuously, in a wide frequency range from DC to 4000 MHz.
Equipped with a 7/16 male connector, integrate this fixed RF load into your system to dissipate up to 50 W continuously over a frequency range from DC to 3000 MHz.
Equipped with a male BNC connector, designed for applications up to 30 W continuous power over a frequency range from DC to 3000 MHz.
Equipped with a male BNC connector, designed for applications up to 30 W continuous power over a frequency range from DC to 3000 MHz.
Ensure reliable and stable dissipation with this compact RF load featuring an N-type male connector, designed to handle up to 2 W continuously over a frequency range from DC to 6000 MHz.
Equipped with a male C connector covering a band from DC to 3 GHz, with a continuous power rating of 2 W.
Designed for high-frequency applications, this RF load with SMA male connector covers a band from DC to 6 GHz and supports 2 W of continuous power.
Ultra-compact and precise, this RF N male connector is designed for low power applications up to 0.5 W continuous, with a bandwidth ranging from DC to 6000 MHz.
Male RF N connector allows continuous dissipation of 30 W over a wide frequency range from DC to 3000 MHz.
Covers a very wide frequency range from DC to 18 GHz.
Ultra-compact and designed for precision, this 50-ohm RF termination offers 2 W continuous power dissipation up to 6 GHz.
Compact and robust, this 50-ohm RF load supports up to 50 W continuously over an extended bandwidth of up to 4 GHz.
Continuous power dissipation up to 100 W, frequency range from DC to 3000 MHz, with an impedance of 50 ohms and a maximum VSWR of 1.30:1.
Covers a wide frequency range from DC to 3000 MHz, with an impedance of 50 ohms and a maximum VSWR of 1.30:1. For your testing and power dissipation needs up to 100 W continuous.
For handling up to 100 W continuously over a frequency range from DC to 3000 MHz.
Equipped with a 7/16 female connector.
Designed with a 7/16 male connector, it covers a frequency range of 200 to 3000 MHz and can dissipate up to 100 W continuously.
Provides reliable dissipation of 150 W continuously over a wide frequency range from DC to 6000 MHz.
Equipped with a 4.3-10 male connector, this 100-watt RF load offers excellent power handling in a frequency range from DC to 4000 MHz.
Continuous power dissipation up to 100 W, frequency range from DC to 3000 MHz, with an impedance of 50 ohms and a maximum VSWR of 1.30:1.
Covers a wide frequency range from DC to 3000 MHz, with an impedance of 50 ohms and a maximum VSWR of 1.30:1. For your testing and power dissipation needs up to 100 W continuous.
For handling up to 100 W continuously over a frequency range from DC to 3000 MHz.
Equipped with a 7/16 female connector.
Designed with a 7/16 male connector, it covers a frequency range of 200 to 3000 MHz and can dissipate up to 100 W continuously.
Provides reliable dissipation of 150 W continuously over a wide frequency range from DC to 6000 MHz.
Equipped with a 4.3-10 male connector, this 100-watt RF load offers excellent power handling in a frequency range from DC to 4000 MHz.
Dissipates up to 5,000 W continuously on the DC band at 862 MHz.
Supports up to 10,000 W continuously, with oil cooling and forced ventilation.
Offers a maximum power of 250 W at 25°C (with linear derating down to 0 W at 125°C). It covers a wide frequency range from DC to 6000 MHz.
Dissipates up to 5,000 W continuously on the DC band at 862 MHz.
Supports up to 10,000 W continuously, with oil cooling and forced ventilation.
Offers a maximum power of 250 W at 25°C (with linear derating down to 0 W at 125°C). It covers a wide frequency range from DC to 6000 MHz.